BEKOTECHNOLOGIESInternational Corporate SiteBEKOTECHNOLOGIESDeutschland | Österreich | SchweizBEKOTECHNOLOGIESIndiaBEKOTECHNOLOGIESBrazilBEKOTECHNOLOGIES責任を通じより良くBEKOTECHNOLOGIES責任心是我們成長的動力BEKOTECHNOLOGIESIreland | United KingdomBEKOTECHNOLOGIESFranceBEKOTECHNOLOGIESBelgique | Pays-Bas | LuxembourgBEKOTECHNOLOGIESItaliaBEKOTECHNOLOGIESSpainBEKOTECHNOLOGIESPolandBEKOTECHNOLOGIESCzech RepublicBEKOTECHNOLOGIESNetherlandsBEKOTECHNOLOGIESCanadaBEKOTECHNOLOGIESUnited States of AmericaBEKOTECHNOLOGIESAmérica Latina

METPOINT® | Sensor Technology

Compare

SD Series Dew Point Sensors
Measuring Principle
Capacitive polymer sensor
Measured Variables
Dew point
Intended Measurement Medium
Compressed air or gases
Measurement Range
-76 to +86 °F td
-22 to +158 °F measured gas temp.
0 to 100% rH
Measuring Accuracy
± 3.5 °F at -40 °F PDP
± 0.9 °F at +15 to +86 °F

Max. Operating Pressure
725 psig
Operating Temperature
-22 to +158 °F

Storage Temperature
-40 to 185 °F
Connection Size | Type
¼" Quick Disconnect Adapter
Analog Output
4...20 mA
Digital Output
Yes
Protection Class
IP65
FS Series Flow Sensors
Measuring Principle
Calorimetric measurement
Measured Variables
Flow and consumption
Intended Measurement Medium
Compressed air or gases
Measurement Range
0.12 to 23,275 scfm


Measuring Accuracy
± 1.5% of reading


Max. Operating Pressure
232 psig standard (725 psig optional)
Operating Temperature
Housing: -22 to +176 °F
Sensor probe: -22 to +284 °F
Storage Temperature
-
Connection Size | Type
½" BSP (ISO 228/1)
Analog Output
4...20 mA
Digital Output
Yes
Protection Class
IP65
SP Series Pressure Sensors
Measuring Principle
Stainless steel thin-film technology
Measured Variables
Relative pressure
Intended Measurement Medium
Gases or liquids
Measurement Range
0 to 232 psig (0 to 870 psig optional)


Measuring Accuracy
≤ ± 0.5%


Max. Operating Pressure
725 psig
Operating Temperature
-40 to +185 °F

Storage Temperature
-40 to 185 °F
Connection Size | Type
¼" BSP
Analog Output
4...20 mA
Digital Output
No
Protection Class
IP67
OCV Series Oil Vapor Sensors
Measuring Principle
Photoionization detection
Measured Variables
Residual oil content
Intended Measurement Medium
Compressed air
Measurement Range
≤ 0.01 to 2.50 mg/m3


Measuring Accuracy
≤ 0.01 to 0.5 mg/m3 ±0.003 mg/m3
≥ 0.5 to 1.0 mg/m3 ±0.10 mg/m3
≥ 1.0 to 2.5 mg/m3 ±0.10 mg/m3
Max. Operating Pressure
232 psig standard (580 psig optional)
Operating Temperature
41 to 122 °F

Ambient Temperature
41 to 113 °F
Connection Size | Type
1/8” female thread, ISO 228-1 standard
Analog Output
4-20 mA analog output
Digital Output
Yes
Protection Class
IP 54

METPOINT® Function Videos

METPOINT® DPM

With the temperature, the relative humidity and the dew point , mobile and stationary dew point measuring devices made by BEKO TECHNOLOGIES precisely measure the critical parameters in compressed air and other gases.

Find even more videos on our YouTube channel.

METPOINT® FLM

Two temperature sensors are installed in series in the direction of flow. The first temperature sensor measures the current process temperature of the compressed air, while the second sensor is electrically heated to a temperature that is 40 K higher than that of the first sensor. Higher volume flows results in a quicker drop in temperature at the sensors, so that the electric heater of the second sensor must increase its heat output. The electric energy required to maintain the temperature difference is proportional to the volume flow. This energy consumption is converted to provide the relevant flow measurements. 

Find even more videos on our YouTube channel.

METPOINT® OCV

METPOINT® OCV is a revolutionary in-line hydrocarbon content sensor. This measurement technology is capable of detecting hydrocarbons down to a range as low as 0.0006 mg/m3 in a compressed air stream.

Find even more videos on our YouTube channel.

METPOINT® Features and Benefits

High Measurement Accuracy
  • Measuring instruments are designed specifically for compressed air applications
Independent Reliability
  • Reliable measurement that is independent of temperature and pressure - no adjustment necessary
Wide Range Connectivity
  • From data logger to networking to mobile systems
Easy to Use Display
  • Simple to use, multi-function displays that are easy to read and are user expandable
Wide Variety of Applications
  • Portable and stationary versions offer users maximum flexibility

METPOINT® Downloads

METPOINT Brochure
Brochure
8 MB
METPOINT DP 109
Manuals DP
2 MB
METPOINT DP 110
Manuals DP
1 MB
METPOINT DP 207
Manuals DP
1 MB
METPOINT SD11
Manuals SD
1 MB
METPOINT SD21
Manuals SD
1 MB
METPOINT SD23
Manuals SD
1 MB
METPOINT SF13 Flow Meter
Manuals FLM
5 MB
METPOINT SF 53 Flow Meter
Manuals FLM
6 MB
METPOINT FS 109
Manuals FS
479 KB
METPOINT FS211 (EN)
Manuals FS
3 MB
METPOINT FS211 (FR)
Manuals FS
905 KB
METPOINT PRM SP11
Manuals SP
1 MB
METPOINT PRM SP21-SP22
Manuals SP
1 MB
METPOINT PRM SP61-SP62
Manuals SP
750 KB
METPOINT LKD Mobile Leak Detector
Manuals LKD
411 KB
METPOINT Spot Drilling Collar
Manuals Spot
226 KB
METPOINT Connect Manual
Software
2 MB